Vapor Chamber and Heat Pipe Heat Sink Design Employed For Cooling of Multiple High-Power Heat Sources Under Varying Operating Conditions
Keywords: Vapor chamber, Heat pipe, Heat sink
Large size heat sinks with vapor chamber and heat pipe base structure are designed for application with multiple high-power heat sources, and measured and simulated under different operating conditions with uniform and non-uniform airflow and power distribution. Study reveals some of the important design considerations for working with these type of two-phase cooling devices and the benefits and drawbacks of the technologies.
Jaana Behm,
Futurewei Technologies
Santa Clara, CA